Inter/Intra exciton transitions from BSE post processing
Inter-exciton transient absorption from BSE post-processing
In this tutorial, we show how to calculate inter-exciton transient absorption by post-processing the Bethe–Salpeter equation (BSE) results with Lumen. The method allows us to compute the transient absorption associated with transitions between excitons. In particular, the initial state can be either a selected excitonic state or a thermal distribution of excitons, including dark excitons with finite center-of-mass momentum.
This approach provides a way to investigate inter-exciton transient absorption without explicitly performing real-time pump–probe simulations. See Refs. [1] [2]. For a tutorial based on real time propagation see Transient Absorption from real-time propagation.
Warning: to perform the following tutorial, it is suggested to work with the develop branch: lumen-develop
Calculate the excitonic states
The ground-state, GW, and BSE calculations can be performed following the standard GW+BSE tutorials available on this wiki.
For inter–exciton transitions, these settings require particular attention in input bse.in:
BSSmod= "d" WRbsWF Lkind= "Lfull" # [BSE] Lbar (default) / full % BSEQptR 1 | Nq | %
Here, Nq denotes the last transferred-momentum index to be included. Replace it with the appropriate value for your calculation.
BSSmod= "d" selects the direct diagonalization method for solving the BSE, providing the excitonic eigenvalues and eigenvectors required for post-processing.
The WRbsWF option stores the excitonic wave functions needed for post-processing.
Lkind = "Lfull" includes the long-range electron–hole exchange interaction responsible for the longitudinal–transverse (L–T) exciton splitting at small finite momenta in 2D materials.
Run the BSE calculation using:
yambo -F bse.in -J BSE
The resulting excitonic eigenvalues and eigenvectors are stored in the BSE/ndb.BS_diago_Q*, where each file corresponds to a different transferred momentum q.
Dipole matrix elements for BSE post-processing
The calculation of exciton–exciton transitions requires single-particle dipole matrix elements, including valence–valence, conduction–conduction, and valence–conduction contributions. Therefore, the DipBandsALL option must be enabled to compute matrix elements between all bands within the selected range. Two approaches can be used to calculate the dipole matrix elements: the length-gauge approach (derk) and the velocity-based approach (G-space v).
Length gauge
For the length-gauge calculation, the position matrix elements are evaluated using the k-space derivative approach, selected by DipApproach= "derk".
Create an input file named dip.in:
dipoles % DipBands 1 | 260 | % DipBandsALL DipApproach= "derk" DipComputed= "" DipoleEtresh= 2 eV
Run the dipole calculation using:
yambo -F dip.in -J DIP_len
The resulting dipole database is stored in the DIP_len/ndb.dipole.
Velocity gauge
For the velocity-gauge calculation, the velocity matrix elements are evaluated using the reciprocal-space approach, selected by DipApproach= "G-space v".
Create an input file named dip.in:
dipoles % DipBands 1 | 260 | % DipBandsALL DipApproach= "G-space v" DipComputed= "" DipoleEtresh= 0.100000E-4 eV
Run the dipole calculation using:
yambo -F dip.in -J DIP_vel
The resulting dipole database is stored in the DIP_vel/ndb.dipole.
The DipBands range must include all valence and conduction bands used in the BSE calculation, not 1-280 attached here..
For the length-gauge calculation, the dipole matrix elements obtained using DipoleEtresh require careful convergence testing, as discussed in a later section. For the velocity-gauge calculation, just use the default of DipoleEtresh.
The dipole databases DIP_len and DIP_vel will be used separately in the subsequent inter–exciton transition calculations.
Inter–exciton transitions from BSE post-processing
The pump pulse initially excites electrons into high-energy continuum states (3.1 eV in experiments of MoS2 monolayer). During the subsequent pump–probe delay, these carriers relax and form excitons, whose populations are assumed to follow a thermal (Boltzmann) distribution, including dark excitons with finite center-of-mass momentum. The subsequent probe pulse induces transitions between excitonic states.
Length gauge
We first calculate the resulting inter-exciton transient absorption spectrum using the length-gauge formulation.
Create an input file named ypp.in:
postbse excexctrans # Final exciton selection FinExccut= 2.5 eV # Exciton temperature EXCTemp= 77.00 K #IniExccut= 0.2 eV # Energy range % EnRngePB 0.00000 | 2.500000 | eV % ETStpsPB= 6401 DampFactorPB= 0.040000 eV # Length gauge Gauge= "length" ConnectEcut= 2 eV GradientA # Only for single-exciton pumping #States= "1 - 2" #% SingleExcPol # 1.000000 | 0.000000 | 0.000000 | #% # Probe polarization % DefDIPdir 1.000000 | 0.000000 | 0.000000 | % DIPplane= "xx yy"
FinExccut controls the selection of final excitonic states, while EnRngePB defines the probe photon-energy range of the calculated spectrum. In this example, both are set to 2.5 eV. For each initially populated exciton, final excitonic states are automatically selected according to the transition energy, given by the difference between the final and initial exciton energies.
EXCTemp specifies the effective exciton temperature used to construct the Boltzmann distribution of initial excitonic populations:
The effective temperature approximates the exciton population at a selected pump–probe delay.
The following three options are used for the length-gauge calculation:
Gauge= "length" ConnectEcut= 2 eV GradientA
Gauge= "length" selects the length-gauge formulation, while GradientA enables the contribution associated with the k-space derivatives of the excitonic amplitudes.
ConnectEcut is used together with the previously calculated length-gauge dipole matrix elements. Its value should be chosen consistently with DipoleEtresh in the dipole calculation.
Both DipoleEtresh and ConnectEcut require convergence tests with respect to the calculated inter-exciton absorption spectrum.
Here, 2 eV is good for MoS2 monolayer.
Before running the calculation, make sure that any ndb.dipole database in the BSE directory (or any other directory specified with -J, except DIP_len) has been renamed to avoid conflicts with the dipole database in DIP_len.
Run the post-processing calculation using the BSE and length-gauge dipole databases:
ypp -F ypp.in -J 'DIP_len,BSE'
The momentum-integrated inter-exciton absorption spectrum is written to an output file of the form: o-*.YPP-TR_eps_sumq_xx.
The first column contains the probe photon energy, and the second column contains the imaginary part of the dielectric response.
Plotting the second column as a function of the first gives the inter-exciton transient absorption spectrum.
Velocity gauge
The inter–exciton transitions can also be calculated using the velocity-gauge formulation.
The input parameters are the same as those used in the length-gauge calculation, except that Gauge is set to "velocity":
Gauge= "velocity"
The length-gauge-specific options ConnectEcut and GradientA should be removed.
The calculation uses the velocity-based dipole matrix elements obtained in Section 2.2, stored in the DIP_vel directory.
Before running the calculation, make sure that any ndb.dipole database in the BSE directory (or any other directory specified with -J, except DIP_len) has been renamed to avoid conflicts with the dipole database in DIP_len.
Run the post-processing calculation using:
ypp -F ypp.in -J 'DIP_vel,BSE'
The resulting inter-exciton absorption spectrum is written to an output file of the form:o-*.YPP-TR_eps_sumq_xx.
As in the length-gauge calculation, the transient absorption spectrum can be obtained by plotting the second column against the first column.
The inter-exciton transient absorption spectra of monolayer MoS2 are compared at 77 and 300 K using the length- and velocity-gauge approaches. In the figure [2], "Direct position" refers to the length-gauge calculation, while "Velocity-derived" refers to the velocity-gauge calculation. The BSE calculations were performed using a 30×30×1 k-point grid.

Single initial exciton
Alternatively, if the pump pulse is resonant with a specific bright exciton, the initial population can be restricted to that excitonic state instead of assuming a thermal Boltzmann distribution. The subsequent probe pulse then induces transitions from the selected initial exciton to other excitonic states. To select a single initial exciton, enable the following options:
States= "1 - 1" % SingleExcPol 1.000000 | 0.000000 | 0.000000 | %
Here, States specifies the initial exciton index, while SingleExcPol defines the pump polarization. The state index should be chosen according to the excitonic state resonant with the pump pulse. EXCTemp should be commented.
References
- ↑ D. Sangalli, M. D'Alessandro and C. Attaccalite, Exciton - Exciton transitions involving strongly bound excitons: an ab-initio approach, Physical Review B 107 (20), 205203 (2023), preprint arXiv: 2211.12241 (2023)
- ↑ 2.0 2.1 T.-X. Qian, M. D'Alessandro, C. Attaccalite, T.-Y. Cai, S. Ju and D. Sangalli Dark exciton signatures in the infrared transient absorption of MoS2 monolayer, preprint arXiv: 2608.30504 (2026)